Compatible Applications
Capsule™ Vitals Stream
Device Manufacturer
Philips Healthcare
Supported Devices
Patient Monitor
- IntelliVue MMS X2 (M3002A)
- IntelliVue MP2
- IntelliVue MP20 (M8001A)
- IntelliVue MP30 (M8002A)
- IntelliVue MP40 (M8003A)
- IntelliVue MP5 (M8105A)
- IntelliVue MP50 (M8004A)
- IntelliVue MP5SC (M8105AS)
- IntelliVue MP60 (M8005A)
- IntelliVue MP70 (M8007A)
- IntelliVue MP80 (M8008A)
- IntelliVue MP90 (M8010A)
- IntelliVue MX400
- IntelliVue MX450
- IntelliVue MX500
- IntelliVue MX550
- IntelliVue MX600
- IntelliVue MX700
- IntelliVue MX750
- IntelliVue MX800
- IntelliVue MX850
- IntelliVue X3
- M2 (M3046A)
- M3 (M3046A)
- M4 (M3046A)
Description of the Release
- Added support for firmware version P with support for all variables up to revision M for the MX series.
- Added Patient State Index variable.
- Added support of StO2 parameters from Hemosphere by adding variable Tissue O2 Saturation variable.
- Added support of the O3 Module. Added Delta Baseline rSO2, rSO2 Baseline, Regional O2 Saturation rSO2-2, Regional O2 Saturation rSO2 and rSO2 Area Under Curve variables.
- Removed support of Fresh Gas N2O Concentration and Fresh Gas O2 Concentration variables. Added Fresh Gas O2 Flow Rate and Fresh Gas N2O Flow Rate variables.
- Marked variables Generic NIBP Systolic Pressure, Generic NIBP Diastolic Pressure, and Generic NIBP Mean Pressure variables as obsolete.
- Added documentation to use Active Alarms and Latched Alarms variables instead of Technical Alarm Description and Patient Alarm Description variables.
- Corrected issue of alarm text having trailing spaces.
- Corrected MDIL code of End Diastolic Volume and End Diastolic Volume Index variables.
- Added known issue about waveforms.
- Added Watchdog Present variable and Watchdog section in the Help File.
- Removed Technical Alarm Source ID, Technical Alarm Global State, Technical Alarm Priority, Technical Alarm Flag, Technical Alarm Priority, Technical Alarm Description, Technical Alarm Internal Source ID, Technical Alarm Source Type, Device Technical Alarm, Patient Alarm Source ID, Patient Alarm Global State, Patient Alarm Priority, Patient Alarm Flag, Patient Alarm Priority, Patient Alarm Description, Patient Alarm Internal Source ID, Patient Alarm Source Type and Patient Alarm multiset variables.
Cases addressed by this Release
- C101709 – 8372, Fresh Gas O2 Concentration does not show up
- C109183 – UMCG: Issue with alarm messages
- C111519 – Philips NIBP timestamp Issue
- C115526 – Philips MX series monitor – Rev P
- C116589 – Variables with new device connected to MX850
- C126655 – Add support for Sto2 parameters for PhilipsDataExport DDI
- C126095 – Yale- Unable to enable/receive waveforms from MX800
- C129507 – support of Rev P firmware version by PhilipsDataExport DDI
- C130583 – Capsule not receiving EDV/EDVI variables from MX800
- C132765 – UMCG: EEG Waveform issue MX750
- C133739 – Request For Psi Data From PhilipsDataExport MX850
- C136959 – CFY cable support for Philips MX 750/800/850
- C142024 – PhilipsDataExport DDI question
- C143133 – Philips Intellivue Rev P?
- C144875 – unable to get ST02 data
- C145562 – UCI – Add PSI Patient State Index to Philips Data Export as is available in PhilipsIIC