anmelden Kontakt
Demo anfordern
Mai 12, 2023

DragerMedibus 5.3.22

Kompatible Anwendungen

Capsule™ Vitals Stream

Gerätehersteller

Draeger

Unterstützte Geräte

Bili Light

  • BiliLux

Infant Incubator

  • Babyleo TN500
  • Caleo
  • Incubator 8000 (IC/SC/NC)
  • Isolette 8000 plus

Infant Warmer

  • Babyroo TN300
  • Babytherm 8004
  • Babytherm 8010

Patientenmonitor

  • Capnosat
  • pEEG
  • PM 8030
  • PM 8040
  • PM 8050
  • PM 8060
  • Vamos
  • Vamos Plus
  • Vitara

Ventilator

  • A300
  • A300 XL
  • A350
  • A350 XL
  • Apollo
  • Babylog 8000 (SC)
  • Babylog 8000 (SC) with slave monitor
  • Babylog 8000plus
  • Babylog 8000plus with slave monitor
  • Babylog VN500
  • Babylog VN600
  • Babylog VN800
  • Carina
  • Cato
  • Cicero B
  • Cicero C
  • Cicero EM
  • Evita
  • Evita 2
  • Evita 2 dura
  • Evita 4
  • Evita Infinity V500
  • Evita Infinity V600
  • Evita Infinity V800
  • Evita V300
  • Evita XL
  • Fabius CE
  • Fabius GS
  • Fabius GS Premium
  • Fabius MRI
  • Fabius OS
  • Fabius plus
  • Fabius plus XL
  • Fabius Tiro
  • Fabius Tiro M
  • Julian
  • Medibus.X compatible device
  • Oxylog 3000 plus
  • Pallas
  • Perseus A500
  • PhysioFlex
  • Primus
  • Primus Infinity Empowered
  • SA2
  • Savina
  • Savina 300
  • Savina 300 Select
  • Sulla
  • Titus
  • Trajan
  • Zeus
  • Zeus Infinity Empowered

Beschreibung der Veröffentlichung

  • Added Device Info and Setting variables for Savina, Evita, Evita 2, Evita 4, Evita 2 dura and Evita XL devices.
  • Added support for the Fabius Tiro M device through the Fabius Tiro and Fabius Tiro [MEDIBUS.X] device entries.
  • Added “+AF” ventilation option for Ventilation Mode.
  • Corrected output of variables when Apnea Ventilation is active.
  • Corrected output behavior of some variables by adding a multiset attribute, for Babylog VN500 [MEDIBUS.X], Babylog VN600, Babylog VN800, Evita Infinity V500 [MEDIBUS.X], Evita Infinity V600, Evita Infinity V800,Evita V300, Medibus.X compatible device and Savina 300 [MEDIBUS.X] devices.
  • Added Alarm Output Interval section in the Help File.
  • Corrected configuration steps for the Perseus A500 device.
  • Corrected communication settings for the Oxylog 3000 Plus device.
  • Added support for Babyroo TN300 device.
  • Added Spo2 Perfusion Index variable.
  • Added Atlan support for Inspiratory Component of I:E Ratio Setting and Expiratory Component of I:E Ratio Setting.

In dieser Pressemitteilung behandelte Fälle

  • C106268 – Draeger Perseus Driver compatibilty with Medbus.X Protocol
  • C105449 – Evita V500 missing ventilation mode variable
  • C108181 – DragerMedibus DDI Surveillance Compatability
  • C100704 – VN500 – Alarms silenced issue.
  • C104296 – Draeger ID 1422
  • C108066 – OLVG: Issue with AutoFLow ventilation mode Perseus A500
  • C115293 – Request for Support for Drager Tiro M
  • C116134 – Wrong Documentation for Oxylog 3000 Plus